Romilly's HART® and Fieldbus Message Board


[ Follow Ups ] [ Post Followup ] [ Back to top of Message Board ]

Multidropping hart devices.

Message posted by Andrew (andrew.barningham@mht-technology.co.uk : 82.69.1.84) on 21 February 2008 at 12:34:10.

I have come accross a situation where there are three gauges which are multidropped, all three gauges are ACTIVE devices. Each device sets an output current to 0.8ma, so a total of (3 x 0.8ma) 2.4ma.
Is this allowed in the hart regulations to multidrop three active devices below 4ma?



Follow Ups:




Post a Followup

Name:
E-Mail:

Subject: Re: Multidropping hart devices.

Comments:


[ Follow Ups ] [ Post Followup ] [ Back to top of Message Board ]